PK-IAT-F 2000 Coating table
The functional principle
Due to the design, the loaded air flow must change direction several times.
Particles that are heavier than air adhere to the walls of the filter due to centrifugal force,
while the cleaned air flow moves through the outlet openings. The accordion design
offers maximum storage space for aerosol deposition with minimum air resistance. The remaining
Aerosol fine dust is then collected in the glass fibre filter.
Energy and air volume-optimised capture system, prepared for connection to an exhaust air system.
The pollutants are extracted via the separator at the rear of the work table.
The separator as a cassette filter can be equipped with various filters and adapted to your pollutants.
Pre-separation of dust and aerosols is therefore possible to protect your exhaust air pipework and the fan
is guaranteed.
Standard equipment
- Height-adjustable feet (mechanical) + 70 mm
- Earthing connection
- stainless steel side curtain rails
- Steel plate 5mm
- 2-fold filter system consisting of 75 mm paper and
50 mm glass fibre filter green or filter
as desired
- Supply air device with aerodynamic
optimised capture element
- LED tube light with adjustable
light angle
Special equipment (at extra cost)
- Exhaust air fan and exhaust air systems
- Colours (RAL) according to customer requirements
- 1 set of louvre side curtains, PCV,
clear, with fastening rail made of V2A or
closed sheet steel version
- 1 set of ANTISTATIC louvre blinds
- Lighting in EX version
zone 1/21 and 2/22
- Supply air fan incl. ventilation system
connections
- Changing the working floor height
by 80 mm using spacers
- Special worktops on request
- External drawer
Technical data | |||
---|---|---|---|
Type | PK-IAT-F 1000 | ||
Work surface width/depth | 1.000/800 mm | ||
Working height | 850 mm | ||
Head height | 2.130 mm | ||
Overall height | 2.350 mm | ||
Total width | 1.200 mm | ||
Total depth | 1.350 mm | ||
Exhaust air | 500 - 2,000 m³/h | ||
Supply air | 600 m³/h | ||
Supply air connection | 2 x DN 80 | ||
Exhaust air connection | 1 x DN 315 |
Note:
If the paint spraying table is set up in an EX area, the required explosion protection must be taken into account for the supply and exhaust air fans.